JISG3455 STS480 Pipe Absorbed energy in Charpy impact test

Remark:
1.The Charpy impact test shall not be imposed on the pipe not affording to provide a test piece 10 x 5 mm.
2.The test piece shall be No. 4 test piece specified in JIS Z 2202 to be cut from a pipe in the longitudinal direction. However, the width of the test piece may be altered to 7.5 mm or 5mm according to the dimensions of the pipe .
3.The test method shall be in accordance with the method of Charpy impact test specified in JIS Z 2242.
4.The test results of Charpy impact test shall conform to the requirements of 1.
5.The method of sampling the test specimens and the number of test pieces shall be as follows. Take one pipe as the specimen from each 100 pipes or its fraction of the concurrent heat treatment, and then from each specimen take one set (3 pieces) of test pieces.
6.Reinspection When the test results fail to satisfy the requirements, a retest may be made to attain final acceptance provided that the average value of absorption energy already obtained satisfies the specified value and also the following conditions are met.

For more information, please refer to:http://boilersteelpipe.com/pro/smls/jisg3455-sts480-pipe-absorbed-energy-in-charpy-impact-test.html